Product Details:

Place of Origin China (Mainland)
Model Number RMF8000
Brand Name Risingmed

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set/Sets
Packaging Details: by carton with foam or on your request
Delivery Time: within 3 days after receving the confirmation receipt
Payment Terms: L/C,T/T,Western Union

Detailed Product Description


8.4'' TFT Screen Maternal/Fetal Monitor with super resolution  

Features:            

  • 8.4 inch super resolution color TFT display
  • Maximum 9 waveforms
  • Use built-in system, high integrated intelligent module technology, full digital monitoring, super functions, lowest * swearing and low failure rate
  • Combined functions of maternal monitor and fetal monitor
  • Measure the intrapartum patient and fetal heart rate
  • Uterine contraction and fetal movement marker
  • Continuous real time recording of fetal heart rate
  • Can be switched to normal patient monitoring interface
  • 72 hours graphic trends and tabular of all parameters
  • 1440 groups of NIBP data storage
  • ST analysis
  • Anti-high frequency electronic surgical unit and anti-defibrillation, for monitoring in the surgery or for cardiac care
  • Use wide-angle, multi-wafer, wide beam and ultrasonic probes

Standard configuration:            

  • FHR, Uterine Contraction Pressure(TOCO), FM and Maternal ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery, thermal printer

Optional:            

  • Dual TEMP

Technical Specifications:

 

Safety

IEC60601 approved (GB9706)
Power source AC100V-240V, 50/60Hz
Size 330mm(L) × 275mm(W) × 160mm(H)
Net weight 5.0 kg
Working Temperature: 5 ~ 40
Humidity <= 85%
Transportation and Storage Temperature: -20 ~ 55
Humidity <= 85%

  

Ultrasonic Probe: (Fetal Heart Rate)

 

Type

Type B proof, dirctional, using pulse doppler system

Working frequency

2.5 MHz

Transmitting power density

1.2m W/cm2

Probe

Multi-wafer probe

Sample rate

5 ms

Calculating precision of FHR

0.25 bpm

Accuracy of FHR

1 bpm (100-180 bpm)

Marker (Fetal Movement)

 

Manually push button mode

When pressed, a red strip will be displayed above the FHR graph

Uterine Contraction Pressure

Type B proof

Uterine contraction pressure probe

Manual zero adjustment

Design pressure sensitivity: 0-100%

ECG

 

Lead

5 leads (R, L, F, N, C)

Lead selection

I, II, III, avR, avL, avF, V

Waveform

7 channels

Gain selection

×0. 5, ×1, ×2

HR and alarm range

Adult: 15-300bpm
Neonate/pediatrics: 15-350bpm

Accuracy

±2% or ±2bpm, whichever is greater

Input impedance

> 5Ω

Voltage range of electrode polarization

±300mV

Leakage current

< 30uA

Filter

Diagnostic mode: 0.05 ~ 100Hz
Monitoring mode: 0.5 ~ 35Hz
Surgical mode: 1 ~ 25Hz

Scaling signal

1mV ± 3%

Measurement range

-1.0mV ~ +1.0mV

Alarm Range

-0.80mV~0.80mV

RESP

Model

RA-LL impedance

Measurement range

Adult: 0 ~ 120bpm
Neonate/pediatrics: 1 ~ 150bpm

Resolution

1rpm

Accuracy

±2rpm

NIBP

Method

Automatic oscillometric

Operation mode

Auto/Manual

Alarm Type

Systolic, Diastolic, Mean

Measurement ranges

Systolic BP: 40 ~ 300mmHg
Diastolic BP: 10 ~ 220mmHg
Mean BP: 20 ~ 240mmHg

Resolution

1mmHg

Accuracy

Max average error ±5mmHg or ±5%, whichever is greater

Overload Protection

Double safety protection

8.4'' TFT Screen Maternal/Fetal Monitor with super resolution LB 8.4'' TFT Screen Maternal/Fetal Monitor with super resolution LB

Send your message to this supplier
« Prev Product ... 22 23 24 25 26 27 28 ... Next Product »

Other Products from this Supplier

Company Info

Beijing Rising Medical Co., Ltd.
[China (Mainland)]
[Verified Member]

Province/State: Beijing
Country/Region : China (Mainland)

Business Type:Manufacturer

View Contact Details

Email this page Bookmark this page Print this Page